FOB CHINA · WORLDWIDE EXPORT
FOB.Dental
Export Equipment Partner
Certified Pre-Owned · American Heritage
锐柯 · CS 9300 Select

Four fields.
One workflow.

The Carestream CS 9300 Select is the versatile core of Carestream's dental imaging family — a single chassis that delivers 5 × 5, 8 × 8, 10 × 5 and 10 × 10 cm volumes, full panoramic, and cephalometric imaging from a Kodak-heritage American platform. One room, three modalities, every FOV you need for general implant, ortho, endo and oral surgery work.

Max 3D FOV
10 × 10 cm
Full dentition, both arches
Voxel Range
90–500 μm
Selectable by FOV & protocol
3-in-1 Modalities
3D · Pan · Ceph
Full cephalometric module
Carestream CS 9300 Select dental CBCT — product studio view showing the main panoramic/3D C-arm with patient positioning arm and separate cephalometric sensor on its dedicated arm
CS 9300 Select · 3-in-1 configuration
Carestream Dental · Atlanta, GA
美国锐柯
Family position

The workhorse Carestream.

CS 9000 3D
5 × 3.7 cm
Single fixed FOV · endo specialist · One-Shot ceph
CS 9300 Select · HERE
Up to 10 × 10 cm
Four selectable FOVs · general practice workhorse
Full CS 9300
Up to 17 × 13.5 cm
Adds skull-base & airway FOVs · maxillofacial
§ 01 · FOV Catalogue

One system. Four clinical personalities.

Every CBCT decision is really a FOV decision. Small field = higher resolution and lower dose but smaller scope; large field = broader view but coarser voxels. The CS 9300 Select lets you make that choice per-patient instead of per-machine — four calibrated volumes, 90 to 500 μm voxels, selected from the same console.

5 × 5
Endo / localized
Scan time12 s
Voxel90 μm
Typical doseLowest
Single tooth, root canal morphology, peri-apical pathology, small cysts, third-molar proximity to IAN.
8 × 8
Quadrant / TMJ
Scan time~20 s
Voxel180 μm (std)
Typical doseLow
Quadrant surgery, single-site implant planning, unilateral TMJ, impacted canines, supernumerary teeth.
10 × 5
Single arch
Scan time~20 s
Voxel180–200 μm
Typical doseModerate
A full maxillary or mandibular arch in a single volume — multi-site implant planning without vertical overkill.
Flagship FOV
10 × 10
Full dentition
Scan time20–28 s
Voxel200–300 μm
Typical doseHigher
Both arches plus adjacent anatomy — full-arch orthognathic planning, bilateral TMJ, comprehensive implant cases.
Dose awareness

Pick the smallest field that answers the clinical question.

The ALARA principle (As Low As Reasonably Achievable) isn't a catchphrase — it's the operating logic of CBCT. A 10 × 10 cm volume carries substantially more dose than a 5 × 5 cm one; using the larger FOV when the clinical question is localised wastes dose and contrast. The CS 9300 Select's four-step catalogue makes that discipline enforceable at the console, not just aspirational on a poster.

Voxel vs FOV trade-off
FOV Min voxel Use case
5 × 590 μmEndo resolution
8 × 8~180 μmSurgical planning
10 × 5~180–200 μmArch planning
10 × 10~200–300 μmFull dentition
Voxel availability shifts with FOV and protocol. The full 90–500 μm range is selectable at the console; we can walk you through recommended presets on delivery.
§ 02 · Three-in-One Architecture

3D, Panoramic, Cephalometric. One chassis.

Two imaging arms, three modalities, one patient positioning system. The cone-beam/panoramic head and the cephalometric arm share the same column and generator — so one room, one install, one calibration cycle replaces what most practices still split across two or three machines.

Modality 01

3D Cone-Beam CT

TFT flat-panel sensor, continuous and pulse scan modes, 12–28 second acquisitions across four selectable fields of view. Reconstructions complete in under two minutes on the recommended workstation.

SensorTFT flat panel
FOV count4 selectable
Voxel90 – 500 μm
Scan time12 – 28 s
Recon time< 2 min
Modality 02

Digital Panoramic

Adaptive panoramic programs for adult and pediatric patients, including segmented pano for localised regions, maxillary sinus views, and double- or quadruple-projection TMJ surveys.

SensorTFT
Exposure4 – 16 s
ProgramsStd · Segmented · Sinus · TMJ×2 · TMJ×4
Modality 03

Cephalometric

CCD scanning cephalostat on a dedicated arm. Five clinical projections from lateral to carpus and five film-size formats up to 30 × 30 cm — full-skull orthodontic capability out of the box.

SensorCCD
Exposure0.1 – 3.2 s
ExamsLat · AP/PA · Oblique · SMV · Carpus
Max format30 × 30 cm
Cephalometric formats

Five acquisition sizes for every orthodontic workflow.

Scanning cephalometric, 0.1 – 3.2 s, 18×18 through 30×30 cm format selection
18 × 18
Pediatric lateral
18 × 24
Standard lateral
24 × 24
AP / PA
24 × 30
Full skull
30 × 30
Maximum
§ 03 · Carestream family map

Three sibling systems. Pick the one that matches your caseload.

We stock both the CS 9000 3D and the CS 9300 Select, and we can source the full CS 9300 on request. Here's an honest, side-by-side look at where each sits — so you buy the one that matches your work, not the one with the most impressive datasheet.

CS 9000 3D
CS 9300 Select ← this page
Full CS 9300
Best for
Endodontics, single-tooth, single-implant
General practice: implant, ortho, endo, surgery
Maxillofacial, airway, orthognathic
3D FOVs
One: 5 × 3.7 cm
Four: 5×5, 8×8, 10×5, 10×10
Seven: adds 17×6, 17×11, 17×13.5
Voxel
Fixed 76 μm isotropic
90 – 500 μm selectable
90 – 500 μm selectable
3D sensor
CMOS + optical fibre
TFT flat panel
TFT flat panel
Cephalometric
"One-Shot" < 1 s
Scanning, 0.1–3.2 s
Scanning, 0.1–3.2 s
Focal spot
0.5 mm
0.7 mm (IEC 60336)
0.7 mm (IEC 60336)
Weight (with ceph)
~199 kg
199 kg
199 kg
Indicative FOB price (used)
$18 – 32 K
$22 – 38 K
$35 – 55 K (on request)

Simple rule of thumb: if every one of your CBCT cases would fit inside a 5 × 3.7 cm window, buy the CS 9000 3D and enjoy the 76 μm voxel and One-Shot ceph. If your cases are general-practice mixed and some of them need a quadrant or both arches, buy the CS 9300 Select — this page. If you routinely image skull-base, airway, or TMJ sweeps beyond the dentition, you want the full CS 9300 and we can source one for you.

See the CS 9000 3D page → for the specialist option, or message us about the full CS 9300.

§ 04 · Clinical applications

Built for mixed caseloads.

The CS 9300 Select's value proposition is precisely the general practice: a single system that handles six common workflows without compromise. Here's how each FOV maps to the clinical reality.

01
Recommended FOV · 10 × 10

Comprehensive implant planning

Multi-site edentulous or partially-edentulous cases where you need to see both arches, the antagonist dentition, and anatomical landmarks (IAN, sinus floor, incisive canal) in a single volume for guided-surgery export.

02
Recommended FOV · 10 × 10 + Ceph

Orthodontic diagnosis & growth assessment

Full-arch volume for impacted teeth, skeletal assessment, and asymmetry, paired with a 24×30 or 30×30 cm lateral cephalogram for standard orthodontic tracing workflows.

03
Recommended FOV · 8 × 8

Oral & maxillofacial surgery

Surgical planning for impacted third molars, supernumerary teeth, cysts and benign lesions — the 8 × 8 FOV gives localised context without committing to full-arch dose.

04
Recommended FOV · 5 × 5

Endodontic diagnosis

Complex root canal morphology, peri-apical pathology, resorption assessment and vertical root fractures at 90 μm voxel — the highest resolution this system offers, matched to a target-sized volume.

05
Recommended FOV · 10 × 5

Single-arch implant workflows

A complete maxillary or mandibular arch captured in one volume without the vertical extent of full-arch scans — ideal for 2-to-4 site implant cases contained within one jaw.

06
Recommended · Panoramic + 8 × 8

Periodontal & general diagnostic

Screening panoramic as the first-line exam, with 3D follow-up on flagged regions using 8 × 8 or 5 × 5 — the workflow most dental practices actually run, without bouncing patients between machines.

§ 06 · CS 3D Imaging software

Native Carestream reading environment.

The system ships with CS 3D Imaging, Carestream's own viewing, reformatting and export suite — handling panoramic, cephalometric and CBCT volumes in a single application with full DICOM 3.0 output.

For third-party implant planning, any supported DICOM-compliant tool opens the volumes natively — including coDiagnostiX, SimPlant, Blue Sky Plan, 3Shape Implant Studio, Anatomage InVivo, and Invivo5.

Included with every delivery
CS 3D Imaging suite
Pano · Ceph · 3D volume viewing & reformatting
MPR reconstruction
Axial · coronal · sagittal · oblique
DICOM 3.0 export
Direct export to any compliant 3rd-party tool
Implant planning module
Included in most versions — licence status confirmed per unit
Cephalometric tracing
Lateral & frontal analysis templates
Airway segmentation
Volumetric airway visualization (higher tiers)
Software version and module availability vary by unit vintage — we confirm exact configuration and licence status before quoting.
§ 07 · Full specifications

Complete technical datasheet.

Section A

X-ray generator

Tube voltage60 – 90 kV
Tube current2 – 15 mA
Frequency140 kHz
Focal spot0.7 mm (IEC 60336)
Input voltage220/230/240 V 50/60 Hz
or 100/110/130 V 50/60 Hz
Section B

3D cone-beam CT

Sensor technologyTFT flat panel
Scan modeContinuous & pulse
Scan time12 – 28 s (± 10%)
Voxel size90 – 500 μm (selectable)
Fields of view5×5, 8×8, 10×5, 10×10 cm
Reconstruction time< 2 min on recommended PC
Section C

Panoramic modality

Sensor technologyTFT
Exposure time4 – 16 s
Exam optionsStandard panoramic · segmented panoramic · maxillary sinus · LA TMJ × 2 · LA TMJ × 4
Section D

Cephalometric modality

Sensor technologyCCD
Exposure time0.1 – 3.2 s
Radiological exam optionsLateral · Frontal AP/PA · Oblique · Submento-vertex · Carpus
Acquisition formats18×18, 18×24, 24×24, 24×30, 30×30 cm
Section E

Physical / mechanical

Weight (without cephalometric)160 kg (353 lb)
Weight (with cephalometric)199 kg (437.8 lb)
Footprint (no cephalostat)1158 (L) × 1595 (D) × 2378 (H) mm
Footprint (with cephalostat)2137 (L) × 1595 (D) × 2378 (H) mm
Detail of the Carestream CS 9300 Select side control panel — showing the yellow X-ray hazard warning label, laser safety compliance label (IEC 60825 class 2, 650 nm), and the tactile up/down movement controls for patient positioner height adjustment
Side control panel & compliance labels
Regulatory & safety

Labelled to international standards.

Each unit retains its original OEM regulatory labelling and IEC compliance markings — ionising-radiation warnings, laser-class positioning-beam labels (IEC 60825 class 2, 650 nm, ≤ 1 mW), and tube-head certification. We supply the original operator manual and service documentation where available, and can verify IEC 60601 medical-electrical compliance markings on the unit before shipment.

§ 08 · Brand heritage

Atlanta, Georgia.
By way of Rochester.

Carestream Dental is the direct corporate successor to Eastman Kodak's Health Imaging division — spun out in 2007, headquartered in Atlanta since, and still carrying the imaging research DNA that shaped medical radiography for most of the 20th century.

That's not a marketing story — it's why parts availability, service documentation, and global dealer coverage remain strong for a platform first released in the early 2010s. You're not buying into an orphaned brand; you're buying a long-lifecycle Western OEM still actively selling the platform today.

Timeline
From Kodak to Carestream
1896
Eastman Kodak Company begins producing X-ray film — the foundation of 20th-century medical radiography.
1985
Kodak enters digital dental imaging research; dental X-ray film is the de facto world standard.
2007
Kodak's Health Imaging business is acquired by Onex Corporation; renamed Carestream Health, with Dental as a full division.
2011
CS 9300 platform introduced — the 3-in-1 pan/CBCT/ceph system that the CS 9300 Select is derived from.
2017
Carestream Dental spun out as a standalone brand — still headquartered Atlanta, still selling and servicing the CS 9300 platform.
2026
CS 9300 family remains in the active Carestream portfolio — parts, service and firmware still supported globally.
§ 09 · Our refurb process

Five stages. Every unit.

Every system we ship goes through the same five-stage protocol. No pre-owned unit leaves our facility without completing the full sequence — whether it's a CS 9300 Select, a Papaya 3D Plus, or any other platform in the catalogue.

01
Inspection

Incoming unit is documented (photos, serial, tube-hour count), functional testing performed on all three modalities, structural assessment of chassis and movement mechanisms.

02
Deep service

Disassembly to subsystem level, full clean of the detector, sensor check, cable harness inspection, replacement of consumables (bite blocks, chin rests, temple stabilizers).

03
Calibration

Geometric calibration using OEM phantoms, dose verification across all four FOVs, panoramic layer-shell calibration, cephalometric magnification check.

04
Test scans

Complete test suite on Alderson / Quart phantoms: 5×5, 8×8, 10×5, 10×10 volumes, panoramic, ceph lateral & AP, exported as DICOM for customer review.

05
Packaging

Unit wrapped, crated in plywood export crate (fumigation-certified for ISPM 15), loaded FOB Shanghai with full documentation pack: commercial invoice, packing list, CE docs, calibration certificate.

§ 10 · Frequently asked

Buyer's questions.

What's the difference between the CS 9300 Select and the full CS 9300? +

They share the same chassis, tube, generator, and sensor hardware. The difference is strictly in the 3D field-of-view catalogue:

  • CS 9300 Select: four FOVs — 5×5, 8×8, 10×5, 10×10 cm
  • Full CS 9300: seven FOVs — adds 17×6, 17×11, 17×13.5 cm (skull-base / airway sizes)

For practices that don't routinely image beyond the dentition, the Select version delivers the same image quality at materially lower cost. Some units are firmware-upgradable, but we don't promise upgrade paths — treat the Select as a Select.

How do I choose between the CS 9000 3D and the CS 9300 Select? +

Two very different tools that share the Carestream name. Pick by caseload:

  • If ≥ 80% of your CBCT cases fit a 5 × 3.7 cm window (endo, single-tooth, single-implant) — and you care about voxel resolution above all else — the CS 9000 3D gives you 76 μm isotropic + One-Shot ceph at lower cost.
  • If you run a mixed caseload — implant planning, ortho, surgery, endo — and some cases need a full arch or both arches, the CS 9300 Select is the right buy.

If you genuinely need skull-base and airway imaging (sleep dentistry, orthognathic surgery, maxillofacial), neither fits — you want the full CS 9300; we can source one.

How does the Select compare to the Genoray Papaya 3D Plus (same price range)? +

Both are 3-in-1 systems in the $22–38 K range, but they come from different design philosophies:

  • CS 9300 Select — American (Carestream/Kodak heritage), four FOVs max 10×10 cm, TFT sensors, CS 3D Imaging software.
  • Papaya 3D Plus — Korean (Genoray), 19 FOV options up to 16×9 cm, three dedicated sensors (one per modality), broader FOV catalogue.

Buy Carestream for heritage brand, Kodak-lineage parts availability, and the cleaner CS 3D Imaging workflow. Buy Papaya for more FOV granularity and dedicated per-modality sensors. Both are good systems; the choice comes down to brand preference and how much you value FOV granularity vs. ecosystem stability.

Is the cephalometric module included by default? +

The cephalometric arm is a factory-option module. We currently stock both configurations — with and without ceph. Weight-wise the 3-in-1 unit is 199 kg vs 160 kg for the pan+3D-only variant, and the footprint extends from 1158 mm to 2137 mm in length with the ceph arm installed. Please specify on enquiry; pricing is $22–28 K for the no-ceph variant and $28–38 K for the full 3-in-1.

What PC hardware do I need to run the reconstructions and software? +

The CS 9300 Select reconstructs in under 2 minutes on Carestream's recommended PC configuration — roughly equivalent to a modern workstation with:

  • Intel i7 / Xeon or AMD Ryzen 7 equivalent, 6+ cores
  • 32 GB RAM (16 GB minimum)
  • NVIDIA discrete GPU with 4 GB+ VRAM
  • 512 GB+ SSD for fast volume I/O
  • Windows 10/11 Pro (64-bit)

We can supply a pre-configured acquisition PC on request, or help spec one to local procurement — confirm at time of quote.

Will Carestream itself support this unit in my country? +

Yes — Carestream Dental maintains a global dealer network and the CS 9300 family remains in their active sales and service portfolio. Direct service contracts with Carestream are typically available in North America, Europe, the Gulf, Southeast Asia and Latin America. In markets without direct Carestream presence, third-party service technicians familiar with the platform are common because of the large global installed base. We'll point you to the nearest support channel as part of delivery.

What's included, and what's the warranty? +

Every shipment includes:

  • CBCT unit (with or without ceph, as ordered), fully assembled and calibrated
  • CS 3D Imaging software media & installation guidance
  • Original operator manual (where available)
  • Calibration certificate from our test run
  • Export-grade plywood crate (ISPM 15 fumigation certified)
  • Commercial invoice, packing list, CE / compliance documentation

Warranty: 3-month limited hardware warranty on tube, generator and detector (extendable to 6 or 12 months on request). Installation and training videos/support provided remotely.

Not included: site preparation, electrical installation, radiation shielding, local import duties or VAT, customs clearance, inland haulage from destination port.

Can you provide test scan DICOMs before shipment? +

Yes, as a matter of course. Every unit gets a final test run on all four FOVs, a panoramic, and a cephalometric (if the ceph module is included). We send the resulting DICOM files — along with full unit photos and the tube-hour report — by cloud link for your review before you approve the shipment.

How does the FOB Shanghai process work? What are my shipping options? +

Under FOB Shanghai, we deliver the crated unit to the vessel at the Port of Shanghai; from that point, ocean freight, insurance and destination handling are your responsibility (you or your freight forwarder). Typical routes:

  • Sea freight (LCL or 20ft FCL): the standard option. Roughly 25-40 days to most major destinations depending on route. Crated dimensions fit one pallet position.
  • Air freight: available for urgent delivery but significantly more expensive given unit weight (~260 kg crated).
  • Express courier: not recommended for this weight class.

We can quote CIF terms as an alternative if you'd prefer we handle ocean freight and insurance — just ask.

Contact

Two ways to reach us. Either works.

We run on WhatsApp and email — no forms, no lead-gen funnels. Messages hit our sales team directly and we respond within one working day.

Company
Shanghai Carejoy Dental Co., Ltd.
上海嘉智医疗器械有限公司
Trade terms
FOB Shanghai · CIF / CIP on request
Payment: 30% T/T deposit, 70% before shipment
Business hours
Mon–Sat · 09:00 – 18:00 (GMT+8)
Response within 24h on enquiries