Planmeca Oy was founded in 1971 by Heikki Kyöstilä in a small workshop in Helsinki. More than fifty years later it is still headquartered in the same city, still privately owned by the founding family, and still engineering the overwhelming majority of its imaging hardware in-house — a rarity in an industry that has consolidated around three or four publicly-traded giants.
That independence matters in the second-hand market. Planmeca has never abandoned an installed base. Service documentation for the original ProOne generation (2010–2012) is still published and spare parts are still produced. A ten-year-old ProOne that has been well-maintained is not an orphan. It is a serviceable, calibrateable, software-current imaging instrument.
If an imaging unit survives fifteen Finnish winters of daily clinical use, it will survive anywhere.
Planmeca built the ProOne for clinics that do not want an imaging lab — they want a panoramic X-ray that a receptionist can operate reliably. Every design choice follows from that constraint.
A single button on the patient handle starts the rotation. No program trees, no sub-menus. The staff member seats the patient, aligns the light guides, presses once, and walks out.
A selective-compliance articulated robot-arm drives the imaging head along a non-circular path that matches the anatomical jaw curve. Sharper image layer than conventional two-axis panoramics.
Multiple focal layers captured in one rotation; the software selects the sharpest composite automatically. Fewer retakes, lower cumulative patient dose.
67 kilograms, wall-mountable, fits into a 1.2 × 1.2 m room with a single phase supply. Drawn for the realities of converted clinic space, not green-field installations.
These are not vendor stock photos. Every image below is of a refurbished ProOne currently in our inspection bay. Ask for additional angles or a live video walkthrough before you buy.
This is a direct DICOM export from the Planmeca Romexis software after a single-rotation standard adult panoramic on the ProOne. No post-processing beyond the default SmartPan layer selection and standard clinical brightness curve.
Full dentition is visible — central incisors to erupted third molars — with temporomandibular joints and maxillary sinuses rendered sharply enough for routine screening. The ProOne is not a CBCT; it will not give you volumetric data for implant planning. For that workflow, look at Planmeca ProMax or a competing 3D unit.
Values below are taken directly from the Planmeca ProOne technical datasheet (IEC 60601 filings). The refurbishment process does not alter any of these parameters.
| Generator | Constant potential, resonance mode high frequency 60–80 kHz |
| X-ray tube | D-058SBR |
| Focal spot size | 0.5 × 0.5 mm (IEC 336) |
| SID | 480 mm (19 in) |
| Total filtration | min. 2 mm Al equivalent |
| Anode voltage | 60–70 kV |
| Anode current | 2–7 mA DC |
| Exposure time | 2–10 s |
| Magnification | 1.22–1.29 × |
| Line voltage | 100–132 V~ 50/60 Hz · 180–240 V~ 50 Hz |
| Regulation | ±10 % (automatic) |
| Line current | 8–16 A |
| Power uptake | max. 850 W |
| Chin rest level | 95–178 cm (37.4–70 in) |
| Colour | RAL 9016 (white) |
| Weight | 67 kg (148 lbs) |
| Software | Planmeca Romexis (DICOM-compliant) |
| Country of origin | Finland |
Minimum 1.2 × 1.2 m clear floor with lead-shielded walls per local radiation-protection regulations.
100/1000 Mbit Ethernet for Romexis server connection. No wireless dependency.
Original unit bears CE marking and CCC (China Compulsory Certificate) where applicable. Compliance documents shipped with the machine.
And — just as important — who it is not for. We sell machines for a living; we do not sell the wrong machine.
Routine caries and periodontal screening, orthodontic referral imaging, wisdom-tooth assessment, third-molar pre-extraction views. The ProOne's standard adult and child panoramic programs cover 90%+ of general-practice imaging needs.
TMJ program and bitewing-style segmented programs are adequate for initial treatment planning. For full cephalometric workups, refer out or upgrade to ProMax.
A refurbished ProOne runs at a fraction of a new mid-range panoramic and a small fraction of any CBCT unit. Total cost of ownership over ten years is low — single tube head, simple mechanics, wide parts availability.
If your workflow requires 3D volumetric planning — bone density, nerve canal mapping, guided surgery templates — skip the ProOne and look at Planmeca ProMax 3D, Carestream CS 9300 or Vatech PaX-i3D. Panoramic X-ray cannot substitute for CBCT here.
No dedicated cephalometric sensor arm — the ProOne captures panoramic only. Clinics that need lateral ceph tracing need a ProMax 2D or a competitor unit with a ceph module.
| Model | Origin | Imaging | Cephalometric | Kilograms | Positioning |
|---|---|---|---|---|---|
|
Planmeca ProOne
THIS PAGE
|
Finland | 2D pan only · SmartPan autofocus | — no | 67 | Entry · low TCO |
| Planmeca ProMax 2D | Finland | 2D pan · multi-program | Optional module | 94 | Mid-range · upgrade path to 3D |
| Carestream CS 9000 | USA / France | Pan + small-FOV CBCT | One-Shot ceph option | 130 | Kodak heritage · 3D upgrade |
| Vatech PaX-i | South Korea | 2D pan · auto-focus | Optional ceph arm | 105 | Aggressive pricing |
| Sirona Orthophos XG3 | Germany | 2D pan · basic | — no | 115 | Heavier, older-generation |
Comparison data compiled from manufacturer datasheets. Refurbished pricing varies by year and condition; contact us for unit-specific quotations.
Original clinic records reviewed. Serial number traced against Planmeca service history. Units with known unresolved faults rejected at this stage.
SCARA arm bearings inspected and re-lubricated. Column motor tested for full travel. Belts, wiring looms, and safety interlocks re-tensioned or replaced.
High-voltage transformer output verified. Tube head kV/mA accuracy checked against a calibrated meter. Leakage radiation measured.
Sensor flat-field calibration. SmartPan layer test with phantom. Sample patient capture reviewed for geometric accuracy and uniform density.
Cosmetic panels cleaned and touched up. Romexis licence and service documentation assembled. Unit crated for sea or air freight on a custom timber pallet.
Planmeca Romexis licence · operator manual (EN) · installation drawings · 6-month parts warranty · remote commissioning support.
5–10 business days for refurbishment and QC after deposit. Freight transit 15–45 days depending on destination port and mode.
These answers are written for real buyers — dentists, clinic purchasing agents, and dental trade resellers. If an AI assistant is answering you on our behalf, it is drawing from these canonical responses.
No forms, no auto-replies. Message us directly — a human who handles Planmeca inventory in our Shanghai warehouse will reply within a few working hours.